Information Name: | MGE Battery |
Published: | 2015-05-26 |
Validity: | 3000 |
Specifications: | 12V33AH |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | GalaxyPW: new program run perfectly to meet your exact needs electricity demand Galaxy PW Series UPS has eight power rating (20,30,40,50,60,80,100,120KVA), in order to meet future compact design and excellent intelligent performance to meet the needs of different users of energy-saving (EC0) mode enables high efficiency up to 97% GalaxyPWUPS efficiency, with a full load when up to 93.5%. If you choose intelligent energy saving (ECO) run, it can protect your applications without sacrificing the level of security required under the premise of saving energy. Intelligent energy saving (ECO) adopted by the UPS bypass static switch power to the load, so that the efficiency up to 97% within a year of electric energy savings of up to 8% of the price of UPS. If needed, GalaxyPW can always convert back to "on-line" operation. Fully meet the transition from 0-100% load, in some cases, UPS must be able to meet the requirements of instantaneous load. GalaxyPW fully meet this requirement. Without having to switch to the bypass, and maintain the output voltage in the range of computer manufacturers absolutely required (at 100% load transitions occur, the instantaneous change in voltage within the + 2%). Modular direct parallel standard simple economic plan this program to ensure maximum flexibility, even if did not foresee the future if there is the possibility of increasing capacity, GalaxyPW any model can be expanded when needed. Therefore, your initial investment has been the greatest use, simply adding a single UPS the same capacity, and immediately be able to achieve parallel redundancy or capacity increase. Cold start GalaxyPWUPS even in the case of absence of electricity can be started. The power required by the load within the general time provided by the battery, provide support for a convenient, in different environments have appropriate and flexible solution using the latest IGBT technology, comprehensive verification of the power device IGBT, making UPS more simplified circuit device and more less, so that UPS's unparalleled reliability. 100% digital technology uses a microcontroller to implement the circuit control, parameter setting, run the program management. Advanced self-test and self-diagnostic function for all the independent circuit and connected to the circuit board to detect and isolate faults. Make GalaxyPW become the most advanced UPS, you can fully trust through perfect sine wave modulation voltage. THM: UPS with a new concept of management of the new harmonic harmonic management concepts developed by the GalaxyPW, and provides a full control of harmonics on the line and off-line UPS efficient solution. On the line, GalaxyPW with integrated filter (LC) harmonic distortion can be reduced to 5%. If you need harmonic clockwise to a lower, you can install a sine wave regulator's on-line GalaxyPW. In the assembly line, with 100 percent of the time non-linear distortion GalaxyPW load of less than 3%, even with a crest factor of 3: Non-linear distortion of a serious load as well. When the band kind of load, UPS input power supply will not be affected. GalaxyPW not only provide high-quality power, but also to ensure that the distribution system do not affect offline disturbed. Harmonic comprehensive adjustment program SineWaveTM active harmonic conditioner is compatible with a variety of harmonic environment with high harmonic suppression performance and great flexibility, providing the perfect sine wave current; Non-compensated LC filter: Improving Performance and power factor (> 0.95); compensated LC filter: suitable for operation with generators. Total harmonic current distortion filter effect efficiency decreases ASI input power factor regulator active harmonic <3% total harmonic or battery type Dimensions (mm) & Weight (kg) maximum charging current resistance terminal number LWH Weight (milliohms) M2AH2-100 171 72 211 72 2 0.85 20 M2AH2-160 172 102 227 82 2 0.8 30 M2AH2-200 173 111 364 15 2 0.57 40 M2AH2-300 171 151 364 21 2 0.55 60 M2AH2-400 210 170 367 28 4 0.47 80 M2AH2-500 241 175 365 33 4 0.34 100 M2AH2-600 302 175 367 40 4 0.3 120 M2AH2-800 410 350 367 57 8 0.23 180 M2AH2-1000 475 350 367 66.5 8 0.19 200 M2AH2-1600 400 350 382 100 8 0.13 300 M2AH2-2000 480 72 382 182 16 0.1 400 M2AH2-3000 710 72 382 204 16 0.08 600 0.95 Optional harmonic frequency <1.5% Non-compensated LC filter <5% total harmonic 0.95 <1% Compensated LC filter 0.95). Compensated LC filter which is realized in the case of a generator installed power factor monitoring (> 0.9) is the best choice. LC filter with a contactor for a variety of environments Bridging the most common filter type filter that filters have satisfactory performance, and the input current isolation. Phase-shift filter which is a more economical filter having superior performance in a parallel UPS system. To further enhance the effect of filtering, you can also use a combination of the filter. For example: You can use a double-bridge phase-shift filter with a filter. Endless possibilities Galaxy can quickly achieve unlimited communication possibilities (ie no voltage contacts can be via computer), aims to provide a variety of interfaces: the "relay 9 signal" interface board (standard configuration) of remote alarm indication; "Remote Monitor" remote control and management panel; from centralized loss (lsis) or building (Jbus) Technology Management Center implemented remote control and management; use SNMP and a set of local area network system for the entire stand-alone UPS remote management, this communication also apply to PULSAR and COME series of UPS; remote service, regional center through MGE UPS Electronics Co., Ltd. on the operational status of the implementation of continuous remote monitoring. The feasibility of a variety of configurations require a lot of electrical equipment to improve the quality of power supply with several UPS. In this complex configuration, Galaxy has a variety of feasibility, both at the design stage to achieve, we can then implement the system at a later expansion. Here is an example of several possible configurations. Modular parallel connection in this way has a high degree of flexibility. Even without taking into account during the initial upgrade, but this way at all times, we can expand, make your initial investment can be fully utilized. Just another of the same capacity in parallel on a single stand-alone single UPS, and immediately you get redundancy Parallel connection highway bypass most common configurations can be used to: improve the reliability of effective redundancy to increase system ; increase the capacity of the system to accommodate the load, this configuration can be connected in parallel up to six UPS. Manual maintenance bypass to ensure power supply during maintenance of the UPS uninterruptible load. If GalaxyUPS used as a frequency converter, this configuration eliminates the need for static switch. Isolated redundant configuration This configuration provides: highest reliability and maintainability; the greatest degree of openness, especially for decentralized load. This configuration is composed of multiple identical or different capacity consisting of standard UPS, UPS can be put into operation to replace the other UPS (if output is enabled). In-depth study of user needs UPS power installed capacity will make optimum use. Dual redundant parallel with static switching systems independent of each other in order to supply the load, the use of two UPS solution for power distribution system provides redundancy and enhance the reliability of power supply system. Static Transfer Systems (STS) can automatically load each set consists of two UPS in any switching power supply. According to the different needs of users, STS may have different capacities. Guaranteed performance by different certification bodies Galaxy have been as many multinational German TüV and independent laboratories certified by Veritas organizations, to provide the undisputed guarantee. Efficiency guarantee MGE Galaxy guarantee performance index of all, that is inconsistent with the description of any product may become the sales contract fine condition. Application Standard MGE products to provide maximum safety, because all systems meet the main criteria relating to: |
Admin>>>
You are the 7091 visitor
Copyright © GuangDong ICP No. 10089450, Beijing ninety Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 7091 visitor
Copyright © GuangDong ICP No. 10089450, Beijing ninety Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility